Posts Tagged :

Storage Stability

Star Oilco diesel fuel truck servicing portable generators on a snowy Portland job site
Do You Need a Diesel Loaner Tank? 1024 768 Star Oilco

Do You Need a Diesel Loaner Tank?

Did you know that Oregon allows temporary diesel tanks onsite for construction projects?

Order off-road diesel for your next construction project in the Portland, Oregon area and Star Oil will loan you a tank with your fuel purchase.

We also have routes to Longview, Washington and Salem, Oregon.

Wethose Fueling for Construction

Take the headache out of fueling your construction project with a temporary tank on the jobsite.

Star Oilco’s goal as a bulk diesel provider is to keep things simple. Make them easy, predictable, and also get the best price for our customers. We love serving construction sites with our mobile, onsite wet-hose service. But we notice sometimes construction projects can sometimes be tricky to fuel.

Planning your project around fuel is not what anyone wants to do. We make it easy by planning for regular stops at a regular time married with bulk equipment to get your price under control.

Generator Fueling Service

Star Oil provides full-service diesel construction fueling, including DEF.

Make sure your diesel generators, light sets, water pumps, air movers, and other project critical equipment are topped off with diesel and DEF.

It can be difficult to keep a construction site fueled with the stops and starts of projects. The coordination required to keep everything moving full speed while adjusting for the unexpected down times caused by subs, permitting, or weather, can be overwhelming. To “keep things simple,” which is our company motto, we know that locating a bulk diesel fuel tank on your jobsite can simplify your project’s fueling complexity. This provides you with a few days worth of fuel when you need it, while also lowering your cost of fuel.

We find that our customers benefit from lower prices and increased up time by placing a temporary bulk diesel tank in their project’s yard. Call Star Oilco for bulk fuel delivery and ask us about our ability to place a tank on your jobsite in the greater Portland ,Oregon or Vancouver, Washington area.

On-demand fueling service available upon request.

Diesel Tank Rental

Star Oilco provides you with single wall 275 gallon and 550 gallon tanks with 110% containment for your short-term construction product at no cost. 550 gallon UL142 Fuel Cubes are also available for longer-term projects or projects requiring the ability to crane a tank. Bigger tanks and card control options are available, too. Whatever your tank need is, we’ll find solutions and make construction fueling easy.

For more information call 503-283-1256, email Dispatch@StarOilco.net or let us know below.

 

Contact Form

  • This field is for validation purposes and should be left unchanged.

 

Star Oilco also can provide fleet cards and wet-hose fueling service for your next project.

Star Oilco’s 6 Reasons to Use Wet Hose Fueling

Star Oilco’s 7 Ways to Stop Fuel Theft Before it Happens

Prepaid and Preset Fuel Cards for Your Small Business 

How to Eliminate Fuel Theft an Save Money

Star Oilco fuel tank and fueling system in a warehouse
Diesel storage tanks UL-2085 needed for modern Fire Code 1024 768 Star Oilco

Diesel storage tanks UL-2085 needed for modern Fire Code

What is required to install a fuel tank in Oregon?

A Tank that meets International Fire Code is a 2 Hour Fire Guard labeled tank.

In recent years Oregon and Washington have been moving to International Fire Code as their adopted standard. Following California with this higher standard of safety as it relates to liquid fuels.  The new standards are far more involved in their construction and therefore their installation as well. Heavy and far more expensive is the most notable standard of a modern Fire Marshall approved tank.

UL 142 – Double Wall Tanks

The old standard for diesel storage was UL-142 (commonly referred to as double wall or “diked tanks” by fleet managers).  These tanks are still made and extremely common throughout the US. If you see one of these tanks for sale and it looks like a great deal it’s probably because of an upgrade requirement causing them to sell it.  Be aware to check code in your local jurisdiction. These tanks still have a wide market for use especially for agricultural zones as well as temporary use with construction sites.

UL 2085 – 2 Hour Fire Guard and Double Wall Tanks

The new standard for storing diesel for refueling vehicles is the UL-2085. This code has been around for gasoline, it is only new in the way that Fire Marshall’s and local municipalities will require it for diesel fuels.

This standard has been around for a long time but typically was used when storing gasoline or more flammable liquids. That standard now applies to diesel fuels as well if they are being installed to refuel equipment, trucks or any other service.  Its worth noting that boilers, HVAC oil furnaces, and other plumbed stationary applications can still use the UL-142 code. Similarly agricultural use in Oregon is allowed a UL-142 use in most applications.  But for fleet fueling even if only a 100 gallon tank the Fire Marshall’s new standard is the UL-2085 concrete lined fire guard tank. It is also worth noting that if you have an installed UL-142 tank in a commercial or industrial zoned property you probably are okay with grandfathered use. But if you want to change anything the Fire Marshall and local Code Enforcement are going to be looking at the newer and safer standard.

Ask your local Fire Marshall to be sure of what the requirements are.

When discussing diesel storage tank options with your local Fire Marshall it helps to see the reason they have the standards they demand. Also be aware of other requirements that local jurisdiction may have. For instance Portland, Oregon’s Bureau of Environmental Services will often demand a cover be placed over the fueling area, an engineered concrete pad beneath it, as well as a potential oil water separator.  Usually there can be an additional permit and process associated with a tank install to meet the needs of a local Fire Marshall as well.

Two hour fire guard or UL-2085 rated tanks are the new standard in Oregon as we have adopted the International Fire Code. and the picture below says a thousand words. It will protect your property from a lake of fire preventing your diesel fuel from feeding disaster.

This is a great picture of a tank being tested for a two hour fire rating by a vendor of Star Oilco’s. Its speaks to why and what is the concern of your local regulator.

Modern Weld Company is a tank manufacturer out of California that makes great tanks to order exactly perfect for your site.

As they make what you need to the specifications you need you can make the Fire Marshall, local City Code enforcement, and your CFO happy at the same time.  If you have questions about installing a bulk diesel fuel tank to either UL-142 or UL-2085 standards give Star Oilco a call. We can help you meet UL codes for diesel, gasoline, biodiesel, or other storage needs.

Close-up of clean diesel fluid stream with light reflections
Tier 4 Engines and Diesel Contaminants – Donaldson White Paper 683 1024 Star Oilco

Tier 4 Engines and Diesel Contaminants – Donaldson White Paper

Managing bulk diesel fuel storage has become more complex in recent years. Especially in Oregon and Washington the chance of water finding it’s way into your fuel tank is a real concern. If water gets in your bulk fuel biological growth or “hum bug” won’t be far behind.  Donaldson has positioned itself with real concrete solutions for for fuel quality.

With the extremely tight tolerances of today’s clean diesel engines and the expansion of sour crudes from tar sands, oil shale, and other source being hydrocracked into today’s ultra low sulfur diesel we have all seen it.  Fuel quality has stayed the same while the tolerance engine manufacturers build to have gotten tighter.

To help fleets solve the fuel quality issues fleet’s are dealing with these days Donaldson Filters has put out an intensive white paper on the what clogs filters.

Titled “Analysis and Identification of Contaminants in Diesel Fuel Filtration and Storage Systems” it goes into a level of depth of what the causes of filter spinning in your fleet is. If you are seeing clogged fuel filters this can help you diagnose and begin to problem solve for your fleet.

Usually diesel engine maintenance costs spin out of control around injector failure, DPF maintenance down time, and recurring regen cycles at the most inconvenient times blowing white smoke everywhere.  Usually this fleet management pain point revolves around dirt and water in diesel fuel.  Problems that Donaldson Filtration is the industry leader in solving.  Aggressive filtration and desicant breathers on tanks will polish your fuel beyond the low standards of petroleum standard ASTM and will exceed the ISO cleanliness standards the OEM’s made your engines to run.

This document is designed as and essential review of diesel contamination as it’s seen from the perspective of a filtration company guarding your diesel engine systems from problems.

This matters as the current generation of clean diesel technology commonly called “Tier 4” engines have a tighter specification need than industry standard diesel specification will meet in practice in the field.

 

The Donaldson Filters White Paper can be seen here: http://www.mycleandiesel.com/Resources/IFC10_FuelContaminants.pdf